AC voltage (terminals 7-8), V | 90 ÷ 420 |
DC voltage (terminals 7-8), V | 100 ÷ 300 |
Rated DC battery voltage (terminals 9-10), V, optional | 8 ÷ 30 |
Supply curcuit frequency range, Hz | 50/60 |
Internal fuse | available |
Max number of events | 5000 |
Clock error, sec/day, sec, not more then | 1 |
Clock standalone operation, when de-energized, years, no less than | 10 |
Setting accuracy, sec | 1 |
Voltage tripping threshold setting accuracy, V | 1 |
Voltage measurement error, %, not more then | 2 |
Illumination intensity measurement error up to 200 lx, %, not more then | 10 |
Illumination intensity measurement error over 200 lx, %, not more then | 20 |
Minimum time for the time relay contacts switching, sec | 0,015 |
Minimum time for the voltage relay contacts switching, sec | 0,035 |
Minimum time for the photo relay contacts switching, sec | 0,1 |
Voltage lower tripping threshold setting range, Umin,V | 90-416, but not more then Umax–dUmax |
Voltage upper tripping threshold setting range, Umax,V | 94-420, but no less than Umin+dUmin |
Min voltage threshold hysteresis dUmin, V | 3 ÷ 9 |
Max voltage threshold hysteresis dUmax, V | 3 ÷ 9 |
Tripping delay for Umin | from 0 sec to 19 min 59 sec |
De-energize tripping delay for Umax* | from 0 sec to 19 min 59 sec |
Load re-energization delay | from 1 sec to 19 min 59 sec |
Illumination level settings range, lux | 0 ÷ 9999 |
Illumination level settings hysteresis, lux | 0 ÷ 999 |
Action delay if illumination is lower than the threshold value | from 0 sec to 99 min 59 sec |
Action delay if illumination is higher than the threshold value | from 0 sec to 99 min 59 sec |
General delay after re-energization | from 0 sec to 99 min 59 sec |
Load relay trip indication | available |
Settings backup in case of circuit and standalone power supply failure | available |
Data memory, years, no less than | 10 |
Computer connection | USB |
Photo sensor cable length, m | 2 |
Distance between the device and the photo sensor, m, not more then | 20 |
Event log | year / month / week / day |
Allowable humidity without condensate, % | 90 |
Protection degree: | ІР20 |
Power consumption (under load), VA, not more then | 3,0 |
Weight, kg, not more then | 0,150 |
Dimensions, mm | 90 х 52 х 66 |
Operating temperature range, °C | from -20 to +55 |
Storage temperature, °C | from -35 to +70 |
Quantity of output relays (channels) | 2 |
Number and type of contacts per channel (changeover contacts) | 1P |
Mounting: | standard 35 mm DIN-rail |
Mounting position: | Any |
* For fastest opening it is recommended to leave the parameter at «00 min 00 sec» value. |